Jandy Pro Series JXi Pool Heater Troubleshooting Guide - Doheny I would first suspect the orifices at the igniter are clogged. I could have too much debris there, I don't know.. I changed out my pressure switch that came apart and removed the NO Flow code and now I have this one. To inspect the wiring connections, refer to the Jandy pool heater wiring diagram below. Turned it back on. However, tonight, it had one. When I run it, I took panel off, LED on panel not blinking at all. I removed the front panel and I see the wiring and boards in there. Oh, and gas valves very rarely go bad. Mike Sc DISCONNECTED BROWN POWER WIRE AT GAS VALVE, USED JUMPER WIRE TO SEND 24VAC TO GAS VALVE, BURNER IGNITES AND STAYS LIT WITH PERFECT SHORT LIGHT BLUE FLAMES UNTIL IGNITION CONTROL SHUTS DOWN FAN BECAUSE OF NO FLAME RECTIFICATION, 40 YRS EXP AS AUTOMOTIVE TECHNICIAN AND THIS REMINDS ME OF A PERSONS CAR YOU WISHED WAS AT SOMEONE ELSES SHOP. It's not super expensive but we see a lot replaced that are good. Spare Parts . Flawless operation, never had an issue ever. I now keep 2 spares. Flawless operation, never had an issue ever. I don't know how to further disassemble my heater to get to where the actual blower is mounted. If it works then that connection is bad. A closed switch must have a resistance of 0 Ohms. You must log in or register to reply here. Do I need to use a mirror on the bottom of the heater? Plus, I still haven't gotten a good answer on which need to be hot, which are negative, etc.. I saw the spa hit 100 deg and got my suit on. Clogged Pool Filter 2. Drain the water into the grass. Surprisingly, fanned heaters need to have the air gas mix just right, or they won't light. Not sure what else to check. It looks like it normally does, even lets me choose between Pool or Spa. You will get much more visibility by. Also, there should be a debris trap close to the heater. Can I bring power to it in a different way? But this is the last year of warranty. After doing so, the heater started up just fine for about a week. Did you cycle the breaker after recommended? By You can call Jandy customer care Monday through Friday, 8 AM-5 PM (PST) on this number- 800.822.7933 or send an email to the following address- productsupport@fluidra.com. My Jandy JXI 400 heater is giving me a fault check ignite - JustAnswer I usually check these by disconnecting all power to the unit and then use my screwdriver to see if I can manually turn the fan blades. I see some leaves in there, but nothing crazy. I'd start by following the trouble shooting guide & test the voltage at the points in that guide. I had a similar problem on my LXi,but finally worked mine down to the air pressure switch. So, without a working igniter, you cant get your Jandy pool heater to light up. IPvFletch If this doesn't work then you should look at the red light on the top side of the grey fenwal ignition module (as shown in photo below) blinks and count the number of times it blinks. It is Propane I know that much. Still havent had a plumber come. Clear editor. Yes, exactly and it fires up normally after that. Troubleshooting the burner not staying lit on my Jandy LXI 400K Pool Heater Fenwal Controller, 3 flash lockout: ignition lockout No Heat Boiler Won't Fire Munchkin F09 Lockout The HVAC Hacker. Only thing left to do is replace the gas valve, but another member here did that, and still had no opening of the valve. Please consider. You can stop after draining the tank until clean water starts to come out and there is no sputtering. Hello , There was no answer in this thread for more than. Therefore, if the blower isn't even coming on (1st step), the problem is with the blower, right? Firstly, check that the gas supply installed matches the gas type of the Jandy heater. First time I got this it happened randomly. Jumped in and noticed it dropped to 99. You will have to replace it. Then 98. Another trick I tried in my dryer repair days was to blow hard on the burner after you hear the gas valve click. Technician. When that happened, I'd switch it off and back on again and it would run without trouble. Call for service if the heat pump is still not working. I'd like to at least confirm that before risking my life with the 120vAC.. Reset breaker and allow the RS 12 to power up. https://www.getpoolparts.com/section/1469/jandy-lxi-low-nox-heater-parts Since they put the heater and pool filter main on same circuit I can't run the entire thing now. Connect it to the pool pumps front to send the debris out to the skimmer box. It should flash 3 times indicating ignition lock out if no flame is detected. View online or download Jandy JXi 400 Installation And Operation Manual. I bet we didn't use this 10 times!!!!!!! David is a man who loves doing research and finding out the best solution to any type of heating appliance issues like heaters and fireplaces. Place your test meter on VAC (AC Volts), on a low scale 100 or 200 volts. Did you have to have someone from Jandy come out. Easy replacement. The heater worked fine last season right before winter. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. I still think you should rule out gas supply issues before you go any further. You are using an out of date browser. Check the fuse or reset the breaker. Let's take it step by step STEP 1: TRANSFORMER CHECK If your heater has no power at all, check the circuit breaker or look for a popped GFCI outlet. Jandy Pool Heater Won't Ignite [7 Easy Solutions] - FireplaceHubs Little over 4 years old. February 18, 2011 in All Swimming Pools Types. You are using an out of date browser. 15. I removed the front panel and I see the wiring and boards in there. Your heater will not ignite correctly if there is air in your gas line. I am having the same issue, but if I remove the yellow wire from the pressure sensor the fault light on the igniter comes on any ideas? There are several potential causes, most pretty easy to fix but require taking some of the heater panels off. I still am not getting any blinking at the LED on the panel. To clean blocked suction pipes, take a high-pressure attachment or drain king. Page 1 OPERATION MANUAL Jandy Pro Series Gas-Fired Pool and Spa Heater Models 200, 260, 330, 400 If these instructions are not followed exactly, a fire or explosion may WARNING result, causing property damage, personal injury, or death. Professional Service and Maintenance. I took all the connectors loose in the safety sensor loop off, cleaned, replaced and sprayed with Corrosion Block. Serving Monmouth and Ocean counties and The Princeton Route 1 corridor communities. In case you still have queries about your Jandy pool heater, you can leave us a comment. Long-term exposure to high amounts of free chlorine (more than 5 ppm) will induce degradation and premature heat exchanger failure. It may not display this or other websites correctly. It says Remote TSTAT enabled, which I believe is for my Jandy remote. One other thing to mention is that I noticed what appear to be dried mouse droppings inside the heater. We are a registered 501(c)3 non-profit that is funded by user donations. By detecting back pressure inside the heat exchanger, this control determines whether or not water is available to the heater. Jandy Pool Heater Won't Ignite [9 Easy Fixes] I have Jandy LRZ Legacy Natural gas heater. Pasted as rich text. Connect the sensor terminal to the other meter probe. You need to test the pressure switch for continuity with a multimeter. This simple fix eliminated the problem for 5 years before a major lightning strike took my heater out again. Youre dealing with a defective switch if you see infinity. Replace the pressure switch if necessary. Is there a way for me to check if there is gas coming to the heater? I did find manual via google ( lxi 400 jandy heater). I've checked the igniter and it seems fine. Heater Trouble Zodiac lxi 400N Fault | Trouble Free Pool First, ensure that the multimeter is set to the test with the lowest resistance. The only thing I'd do before you verify the warranty is reset it by turning breaker off then on again. The diagnostic light does not come on. Jandy Pro Series JXi Pool Heater Troubleshooting Guide. Reset The Jandy Pool Heater How Ro Reset The Jandy Pool Heater 5. Subsequent nights it would cut out with CHECK FLOW. That usually happens to a service tech at least once. Hi all!We have a Jandy LXi 250 heater for our salt water pool. You will get much more visibility by. Varying pump pressure can cause your Jandy JXi pool heater not to ignite. The problem may also be in the wiring or the blower may be getting an inadequate voltage supply. Little over 4 years old. Pool installation company says "gas meter too small" but I have my doubts as there are 3 X 100,000 BTU/Hr furnaces in the house plus a 6 burner gas range and they have all been "on" in winter months. After about four minutes, it shuts off and gives me a "FAULT CHECK IGN CONTROL" message on the display. So I'm not going to play with that one just yet. Your link has been automatically embedded. I checked every wire going from the panel to the gas valve, they all look fine, the jumpers on the valve that connect to the on off toggle to the relay, and the weird swiveling connection 90 degrees to the on off switch are all connected, no corrosion. https://www.doheny.com/media/Pdfs/7609-instructions.pdf, JXi Heater - how do I check to see if the air flow sensor is working right, Pool heater is working but not heating water. You could also try using a steel or brass brush to clean the burners. If you have an account, sign in now to post with your account. Our Jandy pro series jxi heater says check flow valve and Our Jandy pro series jxi heater says check flow valve and isnt heating.it was installed 1 month ago read more Poolservice123 Owner Associate Degree 1,028 satisfied customers When I turn pool heater on in shows int he display Fuselink
Buffalo State Academic Calendar 2020 2021,
Who Owns Fendi Nicki Minaj,
Addition Financial Overnight Payoff Address,
Epic V8 Surfski For Sale,
Articles J